Flags
The Flags indicate the device status. Common device statuses for Wi-Q controllers when they are connected to a portal gateway are below:
- 010001 – Controller initial connection to the gateway.
- 30207 – Controller connected to the portal gateway and is waiting for segment updates.
- 30063 – Controller has a deep reset command pending.
- 30017 – Controller waiting to be pulled into the segment and has not received segment updates.
- 30007 – Controller has received segment updates and is waiting in the ‘New Segment Items’ folder in Wi-Q AMS Configuration software.
- 30043 – Controller is signed into the ACS, connected, configured, and not locked to the portal gateway.
- 30053 – Controller is taking configuration updates.
- 32043 – Controller is signed into the ACS, connected, configured, and locked to the portal gateway.
- 32243 – Controller is locked to the portal gateway but has not been added to an access level or a direct assignment to a User. Either the software has not pushed the user credentials to the controller, or there is not an Access Level, User Group, or Clearance assigned to the reader.
- 38053 – Controller has a firmware update pending.
- 38043 – Controller is receiving a firmware update.
- 32207 – Controller completed the firmware update and is waiting for updates from the portal.
Update Flags That May Be Visible in PEND Column
| S | Segment (PIN length, DST times) |
| C | Card Formats |
| L | Controller configuration (beacon time, channels, transaction masks, etc.) |
| U | Users |
| T | Timezone intervals |
| I | WAC I/O |
| F | Firmware |
| P | Ping (missing LIF data after association or update) |