Electric Latch Retraction |
Instructions
| Document ID | Description |
|---|---|
| T93581 | ELR Wiring Detail and Door Preparation Information |
| T93581_SP | Detalles del cableado de retracción del pestillo eléctrico (Spanish) |
| T93581_FR | Détails du câblage de rétraction du pêne électrique (French) |
| T93580 |
ELR Retrofit Kit Installation Instructions
|
| T93580_SP | Kit de conversión ELR (STD y BF) - ELRK y ELRKF para dispositivos de montante ancho Instrucciones de instalación de NELRK y NELRK para dispositivos de montante estrecho |
| T93580_FR | Trousse de conversion ELR (STD et BF) – ELRK et ELRKF pour dispositifs à montants larges Instructions d’installation NELRK et NELRKF pour dispositifs à montants étroits |
| T93665 | CM150-08 Control Module Wiring Instructions for CM150-05 to ELR |
| T93665_SP | Instrucciones de instalación del módulo de control CM-150-08 (Spanish) |
| T93665_FR | Instructions d’installation du module de contrôle CM-150-08 (French) |
| T93666 |
Power Supply Installation Instructions
|
| T93666_SP |
Instrucciones de instalación de la fuente de alimentación ELR-150 (Spanish)
|
| T93666_FR |
Instructions d’installation de l’alimentation ELR-150 (French)
|
| T93669 | BT150-07 Battery Backup ELR Power Supply Wiring Instruction |
| T93669_SP | Fuente de alimentación ELR con batería auxiliar BT-150-07 Instrucciones de cableado (Spanish) Wiring Instructions(Spanish) |
| T93669_FR | Alimentation ELR de la batterie de secours BT-150-07 instructions de câblage (French) |
Specifications
- Provides remote electric latch retraction for exit devices
- Uses continuous-duty solenoids for momentary unlatching or continuous dogging
- Interfaces with door operators, card readers, switches, and fire alarm systems
Number of Devices |
Door Width |
|---|---|
3 |
2′-7″ to 3′-0″ |
4 |
3′-1″ to 4′-0″ |
The Power Supply model number is determined based on the number of devices requiring electrical power.
ELR Conversion Kit
A standard device can be retrofit to the Electric Latch Retraction option by ordering the kits listed below. A ELR Conversion Kit REQUIRES a ELR150 Series Power Supply. To Order:
Stile Type / Width |
Compatible Devices |
|---|---|
Wide Stile – 3′-0″ |
ELRK-3, ELRKF-3 |
Wide Stile – 4′-0″ |
ELRK-4, ELRK-4 |
Narrow Stile – 3′-0″ |
NELRK-3, NELRKF-3 |
Narrow Stile – 4′-0″ |
NELRK-4, NELRKF-4 |
Note: Power may be supplied through a 4-wire continuous circuit hinge (furnished by others).
Solenoid Specifications
| Operating Mode | Electrical Rating |
|---|---|
| Current Pulse (maximum 2 seconds) | 4.75 amps |
| Continuous Duty | 3.6 VDC at 0.8 amps |
ELR150 Series Power Supply
- Supplies required power for all ELR devices
- Supports up to four plug-in control modules
- Controls one ELR device per control module
- Provides an adjustable latch retraction delay from 0 to 4 minutes
Power Supply Specifications
- Meets UL Class II output requirements
- Complies with UL 294 access control standards
- Protects circuitry using integrated circuit breakers
- Accepts 115 or 230 VAC user-selectable input
- Operates at 115 VAC, 1 amp input
- Supports optional battery backup and power tap
- Displays power status using an LED indicator
- Secures components inside a keyed, lockable enclosure
- Measures 16″ W × 14″ H × 6″ D
- Weighs approximately 15 pounds